看了垃圾焚烧连续在线监测系统的用户又看了
虚拟号将180秒后失效
使用微信扫码拨号
监测参数9/span>SO2?/span>NO?/span>NO2?/span>N2O?/span>CO?/span>CO2?/span>NH3?/span>HCL?/span>HF?/span>H2O?/span>CH4?/span>H2CO以及其它能测量的气体、/span>
应用领域:垃圾焚烧,过程监测以及废气排放监测、/span>
测量组分及量稊/span>
监测项目 |
长气室低量程[Vol%] |
长气室高量程[Vol%] |
短气室高量程[Vol%] |
H2O |
10 |
40 |
|
CO2 |
5 |
30 |
监测项目 |
长气室低量程[mg/m3] |
长气室高量程[mg/m3] |
短气室高量程[mg/m3] |
NH3 |
5 |
230 |
250 |
SO2 |
75 |
5000 |
5000 |
NO2 |
40 |
1000 |
3000 |
NO |
200 |
2000 |
5000 |
CO |
75 |
4000 |
5000 |
N2O |
50 |
1000 |
3000 |
HF |
3 |
300 |
2000 |
HCL |
15 |
2000 |
3000 |
CH4 |
7.5 |
200 |
200 |
注:组分和量程可定制、/span>
性能指标
系统技术指栆/span> |
1?/span>测昼原理:傅立叶变换红外,单台分析仪多组份实时测量分析(*?5种气体组份) |
2、零点漂移:自动修正 |
3、量程漂移:旟/span> |
4?/span>线性偏差:<2%F.S依据EN15267-39/span>2008-3 *低检测限9/span><2%F.S依据EN15267-39/span>2008-3 交叉灵敏度:<4%F.S依据EN15267-39/span>2008-3 |
5、响应时闳/span>'/span>T90):烟气处理之前≣/span>l20s;烟气处理之后≤l20s、/span> |
6、防护等级:lP65 |
7?/span>CaroUsel干涉?/span> |
分辨率:8cm-1 扫描速度9/span>10欠/span>1科/span> 检测器9/span>Peltier制冷MCT |
红外光源9/span>Sic+/span>l550K 分束器:BaF2 窗口9/span>BaF2 波长范围9/span>900 - 4200crn-1 |
8、样气室Sample Cell |
工作温度9/span>l80C 多次反射光程9/span>2.5m 材料9/span>100%黄金涂层 |
反射镜:固定,黄金涂屁/span> 体积9/span>1.07L 接口9/span>Swagelok 6 rnm orll4" 密封9/span>Viton. 0-ring5 |
9、数据接叢/span> |
通讯9/span>RS-232 D垊/span>9孓/span> |
10、采栶/span> |
采样泵:需要外?/span> 样气流量9/span>2-I0L/min 尘过滤要求:2U 样气压力要求:大氓/span> |
11、内置数据处琅/span> |
AID转换器:动态范図/span>95 Db 信号处理器:32-bit浮点DSP 运算速度9/span>120 MFLOPS |
12、电源:220VAC+/span>50HZ |
FTIR系统的特炸/span>
FTIR系统特点 |
1、快速定性、定量分枏/span> |
2、分析组分多,可以同时分?0多个组分、/span> |
3、灵活的量程设置,测量组份和量程可定制、/span> |
4、分析系统全部处?80C高温下运行,不会造成微重有毒物质水溶而造成分析失效,不会造成分析系统的腐蚀和堵塞、/span> |
5、检测限低,适合垃圾焚烧中微量有毒气体的分析、/span> |
6、自动干扰校止/span> |
7、自动零点校准,不需要刻度校准,不需要标准气体、/span> |
8、稳定性好,维护量很小,使用寿命长 |
9、响应迅速,20几个组分的全分析 |
10 增加测重组分无需更改任何的机械部件,只需增加相应的谱图即可、/span> |
傅立叶分析系统监测软仵/span>
用于现场对排放气体的监测和分析,应用于锅炉排放监测,CEMS比对验收,垃圾焚烧排放监测,化工排放监测,催化转化过程研究等领域。特别对亍/span>NH3?/span>HF?/span>HCL等难测气体,是有效的分析手段、/span>